How to do RLA Study of Boiler

Image
  Procedure for RLA Study Power plant equipment and its components are operated into hi temperature, frequent fluctuation of pressure and temperature, frequent start/stop, erosion and corrosion environment. Collect the operation data identify the critical items and formulate plan for inspection. Flow diagram for RLA procedure is like below fig. Boiler RLA: Critical pressure parts of Boiler are: ·        Drum- steam ·        Headers- both steam and water ·        Tubing- Super heater, water wall, economizer ·        Piping- Steam and feedwater ·        Deaerator ·        Attemperator     Testing and Inspection plan for Boiler : Items Testing Drum Visual VI WFMT Wet Fluorescent Magnetic Particle UTT ...